SRK 71 ZR ( TON : 2.1 )

MRP 122,000.00

ECO SMART – HYPER INVERT Presenting India’s Highest Energy Saving (Cooling / Heating): 2.2 Ton Eco Smart Duty AC With R 410 A Refrigerant & Maximum 3.7* EER.

Add to Wishlist
Add to Wishlist
Categories: ,

Description

BEE STAR RATING 5 STAR
COMPRESSOR TYPE Super Tropical – DC PAM Inverter – Return Cooled – Twin Rotary
VFD – VARIABLE FREQUENCY DRIVE INVERTER VECTOR CONTROL TECHNOLOGY FOR HIGHER EFFICIENCY
MINIMUM COMPRESSOR RPM 7 – 15 RPM – USING VECTOR CONTROL TECHNOLOGY
REFRIGERANT  VOLUME CONTROL USING MOTORIZED ELECTRONIC EXPANSION VALUE FOR V ARIABLE REFRIGERANT FLOW
LCD REMOTE CONTROL ( ipM CONTROLLER ) ipM ( INTELLIGENT POWER MODULE )
POWER SOURCE 1 PHASE, 220/230 V, 50 HZ
MAXIMUN COOLING CAPACITY AT*** 120% LOAD BTU / hr 27272
RATED COOLING CAPACITY AT 100% LOAD 25436
RATED COOLING CAPACITY AT 50% LOAD 12966
MAXIMUN COOLING CAPACITY AT*** 120% LOAD Watts 7933
RATED COOLING CAPACITY AT 100% LOAD 7455
RATED COOLING CAPACITY AT 50% LOAD 3800
RATER POWER CONSUMPTION AT 100% LOAD Watts 2000
RATER POWER CONSUMPTION AT 50% LOAD 725
RATED EER / COP AT 100% LOAD W/w 3.7
RATED EER / COP AT 50% LOAD 5.2
RATED INDIAN SEASONAL ENERGY EFFICIENCY ISEER 4.85
CURRENT ( MINIMUM – MAXIMUM ) A 1.40  ~  9.0
MAXIMUM HEATING CAPACITY** BTU / hr 34200
MINIMUM HEATING CAPACITY 6824
RATED HEATING CAPACITY 27300
MAXIMUM HEATING CAPACITY** Watts 10023
MINIMUM HEATING CAPACITY 2000
RATED HEATING CAPACITY 8000
MAXIMUM POWER CONSUMPTION Watts 2060
MINIMUM POWER CONSUMPTION 375
RATED POWER CONSUMPTION 1950
EER AT MAXIMUM HEATING CAPACITY W/w 4.87
EER AT MINIMUM HEATING CAPACITY 5.33
EER AT RATED HEATING CAPACITY 4.1
CURRENT ( HEATING MODE ) A 1.5 – 8.5
DIMENSION ( H * W * D ) INDOOR UNIT mm 339 x 1197 x  262
OUTDOOR UNIT mm 750 x 880(+88) x  340
WEIGHT INDOOR UNIT Kgs 18.5
OUTDOOR UNIT Kgs 60
COOLING COIL ROW INDOOR UNIT NO.S 3
AIR FLOW INDOOR UNIT CMH 1450
LONG REACH AIRFLOW UPTO INDOOR UNIT Meters 18.28
SELF DIAGNOSIS FUNCTION INDOOR UNIT YES
SOUND LEVEL ( H /M/ L ) INDOOR UNIT Db 44/41/37/25 (U – LOW)
LOUVER SWING INDOOR UNIT 3D + 3D AUTO
SPECIAL FILTER INDOOR UNIT ALLERGEN + Solar + Anit Bacterial –  Filter
 BLOWER FAN INDOOR UNIT Anti – Micro Bial
DC FAN MOTOR SPEED INDOOR UNIT Auto / Power / High /Med /Low / ULO(Silent  Mode)/DRY
REFRIGERANT PIPING THICKNESS : 18 GAUGE ( 1mm ) LIQUID LINE mm 6.35 ( 1 / 4″ )
GAS LINE mm 15.88 ( 5/8″ )
MAIN POWER SUPPLY TO OUTDOOR UNIT 2.5 mm * 3 cores  (With Earthing Cable )
CONNECTING WIRING B / W IDU & ODU 2.5 mm * 4 cores  (With Earthing Cable )
OPERATING TEMPERATURE RANGE HEATING C 24 C
AREA COVERAGE*** Sq.Meters 27.87 ~ 41.80